{"product_id":"ise400162l","title":"SMC ISE400162L (ISE40-01-62L) - High-Precision Digital Pressure Switch, R1\/8 Port, 3 m Lead Wire","description":"\u003cp\u003eSMC ISE400162L High-Precision Digital Pressure Switch — R1\/8 port with PNP 2-output plus 1 to 5 V analog output and 3 m lead wire. 0.000 to 1.000 MPa rated pressure range, PNP open collector 2 outputs, 1 to 5 V analog output, R1\/8 port with M5 female thread, 12 to 24 VDC supply, IP65 enclosure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e ISE40-01-62L · \u003cstrong\u003eSKU:\u003c\/strong\u003e ISE400162L\u003c\/p\u003e\u003ch2\u003eISE40-01-62L Applications\u003c\/h2\u003e\u003cp\u003eThe R1\/8 port, PNP 2-output plus analog, 3 m lead wire build of the SMC ISE400162L suits panels where the controller sits well away from the sensing point. It is used in factory automation, packaging and machine-tool compressed-air circuits to monitor positive line pressure. It is suited for clamp and gripper confirmation, air-supply drop detection, and closed-loop pressure trending via the 1 to 5 V analog signal into a PLC analog card. The two independent PNP outputs let one switch serve both an alarm threshold and a process interlock, while the 3-1\/2 digit LED display gives operators a direct local reading during setup and fault-finding.\u003c\/p\u003e\u003ch2\u003eISE40-01-62L Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eISE40-01-62L\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Precision Digital Pressure Switch\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eZSE40\/ISE40 (ISE40, positive pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Pressure Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 MPa\u003c\/td\u003e\n\u003ctd\u003eOperating\/Set Pressure Range\u003c\/td\u003e\n\u003ctd\u003e-0.100 to 1.000 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProof Pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003ctd\u003eApplicable Fluid\u003c\/td\u003e\n\u003ctd\u003eAir, non-corrosive gas, non-flammable gas\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePort Size\u003c\/td\u003e\n\u003ctd\u003eR1\/8 (with M5 x 0.8 female thread)\u003c\/td\u003e\n\u003ctd\u003eSwitch Output\u003c\/td\u003e\n\u003ctd\u003ePNP open collector, 2 outputs, max. load current 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e1 to 5 V, +\/-5% F.S., output impedance approx. 1 kOhm\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e55 mA or less\u003c\/td\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2% F.S. +\/-1 digit or less\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e2.5 ms (anti-chattering 24\/192\/768 ms selectable)\u003c\/td\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3-1\/2 digit LED, sampling 5 times\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC (storage -10 to 60 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLead Wire\u003c\/td\u003e\n\u003ctd\u003e3 m oil-resistant heavy-duty cord, 5-wire (option L)\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 60 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePart Number Decode\u003c\/td\u003e\n\u003ctd\u003eISE40 = positive-pressure digital pressure switch; 01 = R1\/8 port; 62 = PNP 2 outputs + analog output; L = 3 m lead wire\u003c\/td\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by SMC (Mar 2011); replaced by ISE20B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eISE40-01-62L Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/upfiles\/etc\/discon\/en\/oldpdf\/ZSE_ISE40-old-e.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC ISE400162L · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103954579630,"sku":"ISE400162L","price":530.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/17_06_2025_12_36_38_ISE40_01_62L.png?v=1784197241","url":"https:\/\/hydroair.ae\/products\/ise400162l","provider":"HydroAir","version":"1.0","type":"link"}