{"title":"Positioners","description":null,"products":[{"product_id":"ip310031","title":"SMC IP310031 (IP310-031) - Pneumatic Positioner, Rc1\/4 rotary type","description":"\u003cp\u003eSMC IP310031 Pneumatic Positioner — Rotary type, with gauges. IP300-series pneumatic positioner, IP310 rotary type. Supply pressure 0.14 to 0.7 MPa; input signal 0-0.2 MPa; output 0-1 MPa; air connection Rc1\/4. -031 supplied with pressure gauges. Converts a pneumatic input signal into proportional actuator position for rotary control valves. Weight approx. 2.6 kg.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e IP310-031 · \u003cstrong\u003eSKU:\u003c\/strong\u003e IP310031\u003c\/p\u003e\u003ch2\u003eIP310-031 Applications\u003c\/h2\u003e\u003cp\u003eThe IP310-031 is an IP300-series pneumatic positioner (rotary type) that positions a rotary pneumatic actuator in proportion to a pneumatic input signal. With a supply pressure of 0.14 to 0.7 MPa and a 0-0.2 MPa signal, it drives the actuator and feeds back shaft position to hold the commanded angle against load. Supplied with pressure gauges (-031) and Rc1\/4 connections, it is used for accurate throttling control of quarter-turn valves and dampers in process and utility air systems.\u003c\/p\u003e\u003ch2\u003eIP310-031 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eIP310-031\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eIP300 (IP310)\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRotary type pneumatic positioner\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSupply pressure\u003c\/td\u003e\n\u003ctd\u003e0.14 to 0.7 MPa\u003c\/td\u003e\n\u003ctd\u003eInput signal\u003c\/td\u003e\n\u003ctd\u003e0-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e0-1 MPa\u003c\/td\u003e\n\u003ctd\u003eAir connection\u003c\/td\u003e\n\u003ctd\u003eRc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAccessory\u003c\/td\u003e\n\u003ctd\u003e-031 with pressure gauges\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eIP310-031 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/webcatalog\/s3s\/en-jp\/detail\/?partNumber=IP300-030\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC IP310031 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103778353326,"sku":"IP310031","price":1771.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/02_01_2025_15_13_12_IP310_031_SMC.png?v=1784196164"},{"product_id":"ip5100031","title":"SMC IP5100031 (IP5100-031) - Pneumatic-Pneumatic Positioner, Rc1\/4 rotary cam feedback","description":"\u003cp\u003eSMC IP5100031 Pneumatic-Pneumatic Positioner — Rotary cam feedback, with 1 MPa gauge. IP5000\/5100-series pneumatic-pneumatic positioner, IP5100 rotary type (cam feedback). Supply pressure 0.14 to 0.7 MPa; input pressure 0.02 to 0.1 MPa; standard stroke 60 to 100 degrees; sensitivity within 0.5% F.S.; linearity within +\/-2% F.S.; hysteresis within 1% F.S.; repeatability within +\/-0.5% F.S.; air consumption 11 L\/min (ANR) or less at SUP 0.4 MPa; output flow 200 L\/min (ANR) or more at SUP 0.4 MPa; air connection Rc1\/4; enclosure JIS F8007 IP55; ambient\/fluid temperature -20 to 80 C; weight approx. 1.2 kg. Suffix -031 = input 0.02-1 MPa, 1 MPa gauge, opening indicated.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e IP5100-031 · \u003cstrong\u003eSKU:\u003c\/strong\u003e IP5100031\u003c\/p\u003e\u003ch2\u003eIP5100-031 Applications\u003c\/h2\u003e\u003cp\u003eThe IP5100-031 is a rotary-type pneumatic-pneumatic positioner using cam feedback to position quarter-turn actuators over a 60 to 100 degree stroke in proportion to a 0.02 to 0.1 MPa input signal. Supply pressure is 0.14 to 0.7 MPa with Rc1\/4 connections and an IP55 (JIS F8007) enclosure for field use. Sensitivity is within 0.5% F.S. with 200 L\/min output flow, making it suitable for accurate control of rotary control valves, dampers and ball valves in process automation.\u003c\/p\u003e\u003ch2\u003eIP5100-031 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eIP5100-031\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eIP5000\/5100 (IP5100)\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRotary type, cam feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSupply pressure\u003c\/td\u003e\n\u003ctd\u003e0.14 to 0.7 MPa\u003c\/td\u003e\n\u003ctd\u003eInput pressure\u003c\/td\u003e\n\u003ctd\u003e0.02 to 0.1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandard stroke\u003c\/td\u003e\n\u003ctd\u003e60 to 100 degrees\u003c\/td\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003eWithin 0.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-2% F.S.\u003c\/td\u003e\n\u003ctd\u003eAir connection\u003c\/td\u003e\n\u003ctd\u003eRc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eJIS F8007 IP55\u003c\/td\u003e\n\u003ctd\u003eAmbient and fluid temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.2 kg\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eIP5100-031 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/ca01.smcworld.com\/catalog\/BEST-old-en\/pdf\/ip5000_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC IP5100031 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103778418862,"sku":"IP5100031","price":1695.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/02_05_2025_11_19_38_IP5100_031_SMC.png?v=1784196165"},{"product_id":"ip8000030x14","title":"SMC IP8000030X14 (IP8000-030-X14) - Electro-Pneumatic Positioner, ATEX Intrinsically Safe Lever Type, 1.0 MPa Pressure Gauge","description":"\u003cp\u003eSMC IP8000030X14 Electro-Pneumatic Positioner — ATEX intrinsically safe (-X14) lever type with 1\/4 NPT air connection, M20 x 1.5 conduit and 1.0 MPa pressure gauge. Input signal 4 to 20 mA DC, Supply pressure 0.14 to 0.7 MPa, Stroke 10 to 85 mm, Enclosure IP65, ATEX II 2G Ex h ib IICT5..T6 Gb.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e IP8000-030-X14 · \u003cstrong\u003eSKU:\u003c\/strong\u003e IP8000030X14\u003c\/p\u003e\u003ch2\u003eIP8000-030-X14 Applications\u003c\/h2\u003e\u003cp\u003eThe SMC IP8000030X14 is the ATEX-compliant (-X14) variant of the IP8000 lever type electro-pneumatic positioner, adding category 2 intrinsically safe certification, a 1\/4 NPT air connection, an M20 x 1.5 conduit port and a blue cable gland over the standard IP8000. It converts a 4 to 20 mA DC control signal into a proportional pneumatic output to position linear control valve actuators. Typical applications are throttling control valves in oil and gas, petrochemical, chemical and pharmaceutical plants where the positioner must be mounted inside a classified hazardous area.\u003c\/p\u003e\u003ch2\u003eIP8000-030-X14 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eIP8000-030-X14\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectro-Pneumatic Positioner\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eIP8000 \/ IP8100 (IP8000-X14)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePositioner Type\u003c\/td\u003e\n\u003ctd\u003e000 - Electro-pneumatic lever type\u003c\/td\u003e\n\u003ctd\u003ePressure Gauge\u003c\/td\u003e\n\u003ctd\u003e3 - 1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAccessories A\/B\/C\/D\u003c\/td\u003e\n\u003ctd\u003eNone (standard)\u003c\/td\u003e\n\u003ctd\u003eOption\u003c\/td\u003e\n\u003ctd\u003eNil - Standard (not L low temperature, not W indicator plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMade-to-Order Suffix\u003c\/td\u003e\n\u003ctd\u003eX14 - ATEX directive compliance and connection\u003c\/td\u003e\n\u003ctd\u003eATEX Classification\u003c\/td\u003e\n\u003ctd\u003eII 2G Ex h ib IICT5..T6 Gb, category 2 intrinsically safe explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003ctd\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd\u003e0.14 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStroke (Lever Type)\u003c\/td\u003e\n\u003ctd\u003e10 to 85 mm (allowable deflection angle 10 to 30 deg)\u003c\/td\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-0.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAir Connection Port\u003c\/td\u003e\n\u003ctd\u003e1\/4 NPT\u003c\/td\u003e\n\u003ctd\u003eConduit Connection Port\u003c\/td\u003e\n\u003ctd\u003eM20 x 1.5, with blue cable gland\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eJIS F8007, IP65 (conforms to IEC Pub.60529)\u003c\/td\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +80 C (T5) \/ -20 to +60 C (T6)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eAluminum diecast, baking finish with denatured epoxy resin\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eIP8000-030-X14 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/assets\/overseas\/international\/en-jp\/atex\/pdf\/P111-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC IP8000030X14 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103953760430,"sku":"IP8000030X14","price":3994.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/03_07_2026_17_51_38_IP8000_030_X.png?v=1784197234"},{"product_id":"ip8100031jx83q","title":"SMC IP8100031JX83Q (IP8100-031-J-X83-Q) - Electro-Pneumatic Positioner, Rotary Type, NPT1\/4 Air Port, 4-20 mA Output","description":"\u003cp\u003eSMC IP8100031JX83Q Electro-Pneumatic Positioner, Rotary Type — rotary type with NPT1\/4 air port (-X83) and 4 to 20 mA opening current transmission. Rotary type electro-pneumatic positioner, Input signal 4 to 20 mA DC, Opening current transmission 4 to 20 mA DC (positive operation), Air connection NPT1\/4 female (-X83), Electrical connection G1\/2, Pressure gauge 1.0 MPa, Enclosure JIS F8007 IP65 (IEC 60529), TIIS flameproof construction Exd II BT5 with terminal box, CE\/UKCA compliant (Q).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e IP8100-031-J-X83-Q · \u003cstrong\u003eSKU:\u003c\/strong\u003e IP8100031JX83Q\u003c\/p\u003e\u003ch2\u003eIP8100-031-J-X83-Q Applications\u003c\/h2\u003e\u003cp\u003eThe SMC IP8100031JX83Q is used to position rotary control valves - butterfly, ball and plug valves - from a 4 to 20 mA DC controller signal in process plants. It is suited for chemical and petrochemical dosing loops, oil and gas skids, and water treatment flow control, and its TIIS flameproof terminal box and IP65 enclosure allow installation in hazardous and washdown areas. The made-to-order X83 variant supplies an NPT1\/4 female air port for North American piping standards, while the built-in 4 to 20 mA opening current transmission feeds valve position back to the DCS without a separate transmitter.\u003c\/p\u003e\u003ch2\u003eIP8100-031-J-X83-Q Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eIP8100-031-J-X83-Q\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectro-Pneumatic Positioner, Rotary Type\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eIP8000\/8100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e100 - Electro-pneumatic, rotary type\u003c\/td\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAccessories A\u003c\/td\u003e\n\u003ctd\u003eJ - With opening current transmission (4 to 20 mA DC) \/ positive operation\u003c\/td\u003e\n\u003ctd\u003ePressure Gauge\u003c\/td\u003e\n\u003ctd\u003e3 - 1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003e1 - With terminal box (Exd II BT5), TIIS explosion-proof\u003c\/td\u003e\n\u003ctd\u003eAir Connection\u003c\/td\u003e\n\u003ctd\u003eNPT1\/4 female (per made-to-order -X83)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003ctd\u003eMade-To-Order\u003c\/td\u003e\n\u003ctd\u003e-X83 - Rotary type with 4 to 20 mA output, NPT1\/4 (female) air port\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eJIS F8007 IP65 (IEC 60529)\u003c\/td\u003e\n\u003ctd\u003eExplosion Proof Structure\u003c\/td\u003e\n\u003ctd\u003eTIIS withstand pressure explosion proof (Exd II BT5)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eQ - CE\/UKCA compliant\u003c\/td\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eAluminium die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eIP8100-031-J-X83-Q Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/ca01.smcworld.com\/catalog\/en\/keiso\/IP8_00_IP8_01-E\/6-11-p0124-0148-ip8_en\/data\/6-11-p0124-0148-ip8_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC IP8100031JX83Q · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103954055342,"sku":"IP8100031JX83Q","price":4997.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/22_12_2025_10_22_07_IP8100_031_J_X83_Q_SMC.png?v=1784197236"}],"url":"https:\/\/hydroair.ae\/collections\/positioners.oembed","provider":"HydroAir","version":"1.0","type":"link"}