{"title":"Fieldbus Modules","description":null,"products":[{"product_id":"ex120scs1","title":"SMC EX120SCS1 (EX120-SCS1) - Serial Interface Unit, CompoBus\/S 16-output","description":"\u003cp\u003eSMC EX120SCS1 Serial Interface Unit — CompoBus\/S SI unit, 16 outputs, plug-in. EX120 series Fieldbus System (for output) SI unit, Type 1 output type for solenoid valves. Protocol OMRON CompoBus\/S; 16 outputs (SCS1); I\/O occupation 0\/16; plug-in valve interface (0). Output type sink\/NPN (positive common); load solenoid valve with surge suppressor 24 VDC 2.1 W or less. Control power 14 to 26.4 VDC, valve power 24 VDC +10\/-5%. Enclosure IP20; operating temp 0 to 55 C (8 pts on) \/ 0 to 50 C (16 pts on); weight 110 g or less. CE\/UKCA marking. Compatible with SV1000\/2000\/3000\/4000, VQ1000\/2000, SY3000\/5000\/7000 manifolds.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX120-SCS1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX120SCS1\u003c\/p\u003e\u003ch2\u003eEX120-SCS1 Applications\u003c\/h2\u003e\u003cp\u003eThe EX120-SCS1 is a serial transmission (reduced-wiring) SI unit that connects an SMC manifold solenoid valve block to an OMRON CompoBus\/S network, cutting the multi-core wiring normally required to drive each valve. It handles up to 16 outputs with sink\/NPN drive and mounts as a plug-in unit to compatible SV, VQ and SY manifolds. Used in machine and line automation to reduce control cabling, ease installation and simplify diagnostics on manifold valve assemblies driven from a PLC over the CompoBus\/S serial bus.\u003c\/p\u003e\u003ch2\u003eEX120-SCS1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX120-SCS1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX120\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSerial interface (SI) unit for solenoid valves\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eOMRON CompoBus\/S\u003c\/td\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eI\/O Occupation\u003c\/td\u003e\n\u003ctd\u003e0\/16\u003c\/td\u003e\n\u003ctd\u003eValve Interface\u003c\/td\u003e\n\u003ctd\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSink\/NPN (positive common)\u003c\/td\u003e\n\u003ctd\u003eControl Power\u003c\/td\u003e\n\u003ctd\u003e14 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eValve Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC +10\/-5%\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e110 g or less\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX120-SCS1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/upfiles\/etc\/discon\/en\/oldpdf\/EX120-SCS1-old-e.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX120SCS1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103773896878,"sku":"EX120SCS1","price":1589.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/19_09_2025_11_09_28_EX120_SCS1.png?v=1784196118"},{"product_id":"ex122scs2","title":"SMC EX122SCS2 (EX122-SCS2) - Serial Interface Unit, CompoBus\/S","description":"\u003cp\u003eSMC EX122SCS2 Serial Interface Unit — CompoBus\/S SI unit, 8 outputs. SMC EX122-SCS2 is a serial transmission (SI) unit for the OMRON CompoBus\/S network, part of the EX120\/121\/122 reduced-wiring output system for manifold solenoid valves. The SCS2 variant occupies 0 inputs\/8 outputs (I\/O occupation 32\/32) and drives up to 8 solenoid valve points with Sink\/NPN (positive common) output at 24 VDC, 2.1 W or less. Communication speed is 750 kbps. Control power supply 14 to 26.4 VDC; valve power 24 VDC +10%\/-5%. Internal current consumption 100 mA or less. IP20 enclosure. Operating temperature 0 to 55 C (8 points ON) \/ 0 to 50 C (16 points ON). CE\/UKCA marked. The EX122 housing mounts directly (without ribbon cable) for SY3000\/5000 series manifolds.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX122-SCS2 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX122SCS2\u003c\/p\u003e\u003ch2\u003eEX122-SCS2 Applications\u003c\/h2\u003e\u003cp\u003eUsed on SMC SY-series valve manifolds to control solenoid valves over an OMRON CompoBus\/S serial network, cutting point-to-point wiring between a PLC and the manifold. The 8-output SCS2 variant suits smaller manifolds where a compact, low-cost reduced-wiring node is needed. Its IP20 rating targets in-cabinet or protected panel mounting rather than washdown environments. Set node address and fail-safe via switches; connect the CompoBus\/S line and 24 VDC valve\/control power.\u003c\/p\u003e\u003ch2\u003eEX122-SCS2 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX122-SCS2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eOMRON CompoBus\/S\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSI Unit (8 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSink\/NPN (positive common)\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e750 kbps\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX120\/122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX122-SCS2 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/upfiles\/etc\/discon\/en\/oldpdf\/EX120-SCS1-old-e.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX122SCS2 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774027950,"sku":"EX122SCS2","price":1303.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/22_04_2024_11_54_26_EX122_SCS2_SMC.jpg?v=1784196119"},{"product_id":"ex122spr1b","title":"SMC EX122SPR1B (EX122-SPR1-B) - Serial Interface Unit, PROFIBUS DP","description":"\u003cp\u003eSMC EX122SPR1B Serial Interface Unit — PROFIBUS DP SI unit, 16 outputs. SMC EX122-SPR1-B is a PROFIBUS-DP serial interface (SI) unit for the EX120\/121\/122 reduced-wiring output system, controlling SMC manifold solenoid valves over PROFIBUS-DP (per IEC 61158 \/ EN 50170). It operates as a passive slave and drives 16 output points (max. 16 single or 8 double solenoids) with Minus (negative) common output at 24 VDC, max. 2.1 W per output. Baud rate is auto-detected up to 12 Mbit\/s. Node address is set via two rotary switches (HW addressing) or via the bus protocol (SW addressing) using the appropriate GSD file. Bus connection is a 9-pin D-Sub; power is a 5-pin round connector with separate 24 VDC (+\/-10%) supplies for electronics and valves. IP20 enclosure, operating temperature 0 to +50 C. CE marked. The EX122 housing mounts directly on SY3000\/5000 manifolds.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX122-SPR1-B · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX122SPR1B\u003c\/p\u003e\u003ch2\u003eEX122-SPR1-B Applications\u003c\/h2\u003e\u003cp\u003eConnects an SMC SY-series valve manifold to a PROFIBUS-DP network as a slave node, replacing individual valve wiring with a single bus cable to the PLC. The 16-output EX122-SPR1-B suits mid-size manifolds and is addressed by front rotary switches for quick commissioning. The IP20 housing is intended for panel or enclosure mounting. Integrate using the SMC GSD file matching the chosen addressing mode; auto baud detection simplifies setup across mixed-speed networks.\u003c\/p\u003e\u003ch2\u003eEX122-SPR1-B Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX122-SPR1-B\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS-DP\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSI Unit (16 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNegative common\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003eup to 12 Mbit\/s\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX120\/122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX122-SPR1-B Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/content2.smcetech.com\/pdf\/si\/si_manuals\/EX120-SPR1-B.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX122SPR1B · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774126254,"sku":"EX122SPR1B","price":4162.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/19_12_2023_12_02_38_EX122_SPR1_B_SMC.png?v=1784196120"},{"product_id":"ex240ie1","title":"SMC EX240IE1 (EX240-IE1) - Input Unit, Digital Input","description":"\u003cp\u003eSMC EX240IE1 Input Unit — Digital input (DI) unit, 8 inputs. SMC EX240-IE1 is a digital input (DI) unit for the EX240 serial transmission fieldbus system used with SMC valve manifolds. It provides 8 input points and connects to the EX240 SI\/gateway unit (e.g. EX240-SIB1), receiving sensor signals and passing them to the network. Up to 8 DI units can be connected to the SI unit, with a maximum communication cable length of 400 m; the system supports up to 32 input points total. Input device supply is 24 VDC via M12 connectors. Enclosure IP65\/IP67 class per the EX240 series. The EX240-IE1 works with SMC directional-control valve manifolds as part of a reduced-wiring input\/output node.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX240-IE1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX240IE1\u003c\/p\u003e\u003ch2\u003eEX240-IE1 Applications\u003c\/h2\u003e\u003cp\u003eAdds sensor input capability to an EX240 reduced-wiring valve-manifold node, letting field sensors report back to the PLC over the same serial network that drives the solenoid valves. The 8-point EX240-IE1 daisy-chains to the EX240 SI\/gateway; multiple DI units expand input capacity toward the 32-point system maximum. Suited to machines needing distributed I\/O near pneumatic actuators without running individual sensor wires back to the controller.\u003c\/p\u003e\u003ch2\u003eEX240-IE1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX240-IE1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX240 serial transmission\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDigital Input Unit (8 inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX240-IE1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcpneumatics.com\/pdfs_smc_instructional\/ex240-sdn2_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX240IE1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774191790,"sku":"EX240IE1","price":266.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/08_07_2024_12_42_05_EX240_IE1_SMC.jpg?v=1784196121"},{"product_id":"ex240spr1","title":"SMC EX240SPR1 (EX240-SPR1) - Serial Interface Unit, PROFIBUS DP","description":"\u003cp\u003eSMC EX240SPR1 Serial Interface Unit — PROFIBUS DP SI unit. SMC EX240-SPR1 is a PROFIBUS-DP serial interface (SI) unit for the EX240 serial transmission fieldbus system used with SMC valve manifolds. It acts as the network gateway\/SI unit connecting the manifold to a PROFIBUS-DP master, controlling solenoid valve outputs and, together with EX240 DI units, gathering distributed sensor inputs. The EX240 modular system supports up to 32 inputs\/32 outputs with communication cable lengths to 400 m. Power is 24 VDC. The unit is configured with the SMC GSD file downloadable from the SMC website. It integrates with SMC directional-control valve manifolds as a reduced-wiring node.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX240-SPR1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX240SPR1\u003c\/p\u003e\u003ch2\u003eEX240-SPR1 Applications\u003c\/h2\u003e\u003cp\u003eServes as the PROFIBUS-DP head unit for an EX240 valve-manifold node, driving solenoid valves and consolidating I\/O onto one bus cable to the PLC. Combined with EX240-IE1 input units, it forms a distributed input\/output station near the pneumatics, reducing field wiring. Commission by loading the SMC GSD file into the PROFIBUS master and setting the node address; suited to line-control and machine-automation systems standardized on PROFIBUS-DP.\u003c\/p\u003e\u003ch2\u003eEX240-SPR1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX240-SPR1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS-DP\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSI Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX240-SPR1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcpneumatics.com\/pdfs_smc_instructional\/ex240-spr1_eng.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX240SPR1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774290094,"sku":"EX240SPR1","price":2644.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/05_12_2024_17_38_16_EX240_SPR1.png?v=1784196122"},{"product_id":"ex245dx1","title":"SMC EX245DX1 (EX245-DX1) - Digital Input Module, Digital Input, Input Module","description":"\u003cp\u003eSMC EX245DX1 Digital Input Module — 16-input digital input module, PNP. SMC EX245-DX1 is a digital input module for the EX245 fieldbus system used with SMC valve manifolds. It provides 16 PNP digital inputs via M12 (5-pin) connectors, operating on 24 VDC. Input specification: ON voltage 11 to 30 V, OFF voltage -3 to 5 V, typical input current 4.5 mA at 24 VDC. It offers short-circuit protection with max. supplied current 0.5 A per connector \/ 2 A per module. Up to 8 modules can be connected to one EX245 manifold, and the EX245 system supports connection to up to 32 solenoid valves plus modular digital input\/output. The EX245 series provides high protection (IP-rated washdown) modular I\/O for SMC directional-control valve manifolds.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX245-DX1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX245DX1\u003c\/p\u003e\u003ch2\u003eEX245-DX1 Applications\u003c\/h2\u003e\u003cp\u003eExpands an EX245 valve-manifold node with 16 PNP sensor inputs, letting field devices report to the fieldbus master alongside the manifold's valve outputs. Up to eight EX245-DX1 modules stack on one manifold for high input density near the pneumatics, reducing sensor wiring back to the cabinet. Per-connector short-circuit protection guards field faults. Suited to modular machine builds where digital input needs to sit at the manifold rather than in a remote I\/O rack.\u003c\/p\u003e\u003ch2\u003eEX245-DX1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX245-DX1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX245 fieldbus module\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module (16 inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePNP\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eM12 (5-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX245-DX1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex245_omu0020en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX245DX1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774355630,"sku":"EX245DX1","price":1148.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/xdOgYN0VBoliZaRmDKVHTh6dhLINi5dXFttQav2dOymIZTSUzHEDVRTWYeeh.jpg?v=1784196123"},{"product_id":"ex250ie2","title":"SMC EX250IE2 (EX250-IE2) - Input Block, Digital Input","description":"\u003cp\u003eSMC EX250IE2 Input Block — Input block, M12, 4 inputs. SMC EX250-IE2 is an input block for the EX250 integrated input\/output fieldbus system used with SMC valve manifolds. It provides 4 inputs via an M12 (5-pin) connector and accepts PNP or NPN sensor input (selectable by switch). Input device supply is 24 VDC, max. 30 mA\/point, rated input current approx. 8 mA, with a 0.5 A fuse for overcurrent protection. Enclosure IP67, operating temperature -10 to +50 C, weight 90 g. Input blocks attach to any EX250 SI unit (EtherNet\/IP, DeviceNet, PROFIBUS DP, AS-Interface); the total of input\/output\/power blocks per SI unit is 10 stations max., up to 32 inputs. CE\/UKCA and UL listed. Note: the EX250 series is to be discontinued (consider EX260\/EX600).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX250-IE2 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX250IE2\u003c\/p\u003e\u003ch2\u003eEX250-IE2 Applications\u003c\/h2\u003e\u003cp\u003eAdds four sensor inputs to an EX250 valve-manifold node so field devices report over the same fieldbus that drives the solenoid valves. The M12 EX250-IE2 selects PNP or NPN sensors by switch and stacks with SI, output and power blocks toward the 10-station\/32-input system limit. Its IP67 rating suits dusty or washdown areas at the machine. For new designs SMC recommends the EX260\/EX600 series, as EX250 is being discontinued.\u003c\/p\u003e\u003ch2\u003eEX250-IE2 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX250-IE2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX250 input block\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eInput Block (4 inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePNP\/NPN (switch selectable)\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eM12 (5-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX250\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX250-IE2 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/catalog\/en\/directional\/EX-S-E\/7-1-3-p1341-1364-EX250_en\/data\/7-1-3-p1341-1364-EX250_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX250IE2 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774453934,"sku":"EX250IE2","price":425.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/16_05_2023_13_30_51_EX250_IE2_SMC.jpg?v=1784196125"},{"product_id":"ex250ie3","title":"SMC EX250IE3 (EX250-IE3) - Input Block, Digital Input","description":"\u003cp\u003eSMC EX250IE3 Input Block — Input block, M8, 4 inputs. SMC EX250-IE3 is an input block for the EX250 integrated input\/output fieldbus system used with SMC valve manifolds. It provides 4 inputs via M8 (3-pin) connectors and accepts PNP or NPN sensor input (selectable by switch). Input device supply is 24 VDC, max. 30 mA\/point, rated input current approx. 8 mA, with a 0.5 A fuse for overcurrent protection. Enclosure IP67, operating temperature -10 to +50 C, weight 90 g. Input blocks attach to any EX250 SI unit (EtherNet\/IP, DeviceNet, PROFIBUS DP, AS-Interface); the total of input\/output\/power blocks per SI unit is 10 stations max., up to 32 inputs. CE\/UKCA and UL listed. Note: the EX250 series is to be discontinued (consider EX260\/EX600).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX250-IE3 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX250IE3\u003c\/p\u003e\u003ch2\u003eEX250-IE3 Applications\u003c\/h2\u003e\u003cp\u003eProvides four M8-connector sensor inputs on an EX250 valve-manifold node, ideal where compact M8 sensor cabling is preferred over M12. The EX250-IE3 selects PNP or NPN sensors by switch and stacks with SI, output and power blocks toward the 10-station\/32-input system limit, all IP67-rated for machine-side mounting. For new designs SMC recommends the EX260\/EX600 series, as EX250 is being discontinued.\u003c\/p\u003e\u003ch2\u003eEX250-IE3 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX250-IE3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX250 input block\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eInput Block (4 inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePNP\/NPN (switch selectable)\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eM8 (3-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX250\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX250-IE3 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/catalog\/en\/directional\/EX-S-E\/7-1-3-p1341-1364-EX250_en\/data\/7-1-3-p1341-1364-EX250_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX250IE3 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774519470,"sku":"EX250IE3","price":425.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/16_04_2026_12_03_28_EX250_IE3.png?v=1784196127"},{"product_id":"ex250spr1","title":"SMC EX250SPR1 (EX250-SPR1) - Serial Interface Unit, PROFIBUS DP","description":"\u003cp\u003eSMC EX250SPR1 Serial Interface Unit — PROFIBUS DP SI unit, 32\/32 I\/O. SMC EX250-SPR1 is a PROFIBUS-DP serial interface (SI) unit for the EX250 integrated input\/output fieldbus system used with SMC valve manifolds. As a PROFIBUS-DP slave it controls up to 32 solenoid valve outputs and, with EX250 input blocks, handles up to 32 inputs (I\/O occupation 32\/32). PROFIBUS-DP version DP-V0; communication speeds 9.6 k to 12 Mbps (auto-detected). Output is Source\/PNP (negative common); valve load 24 VDC, 1.5 W or less. Enclosure IP67. Configured via the SMC GSD file. Connects SMC directional-control valve manifolds (VQC, SV, SY, S0700) as a reduced-wiring node. Note: the EX250 series \/ EX250-SPR1 is discontinued; SMC recommends the EX600 series as a substitute.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX250-SPR1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX250SPR1\u003c\/p\u003e\u003ch2\u003eEX250-SPR1 Applications\u003c\/h2\u003e\u003cp\u003eHead unit that puts an EX250 valve manifold onto a PROFIBUS-DP network, driving up to 32 valve outputs and consolidating up to 32 sensor inputs (via input blocks) onto one bus cable to the PLC. IP67 rating allows machine-side mounting in dusty or washdown areas. Commission by loading the SMC GSD file and setting the node address. As EX250-SPR1 is discontinued, plan EX600-series equivalents for new builds while servicing existing installations.\u003c\/p\u003e\u003ch2\u003eEX250-SPR1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX250-SPR1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS-DP (DP-V0)\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSI Unit (32 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSource\/PNP (negative common)\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBaud Rate\u003c\/td\u003e\n\u003ctd\u003eup to 12 Mbps\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX250-SPR1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex250-spr1_profibus-dp_en-f.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX250SPR1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774585006,"sku":"EX250SPR1","price":2269.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/16_05_2023_14_11_57_EX250_SPR1_SMC.jpg?v=1784196127"},{"product_id":"ex260sec1","title":"SMC EX260SEC1 (EX260-SEC1) - Serial Interface Unit, EtherCAT","description":"\u003cp\u003eSMC EX260SEC1 Serial Interface Unit — EtherCAT SI unit, 32 outputs. SMC EX260-SEC1 is an EtherCAT serial interface (SI) unit for the EX260 integrated fieldbus system, controlling up to 32 solenoid valve outputs on SMC valve manifolds. Output type is Source\/PNP (negative common). EtherCAT runs in Direct Mode (no MAC address) at 100 Mbps over standard Ethernet (CAT5), supporting up to 65,535 nodes in daisy-chain topology with segment length to 100 m. It has BUS IN and BUS OUT M12 4-pin D-coded connectors and a 5-pin M12 A-coded power connector. IP67 enclosure for dust and washdown protection. Configured via the SMC EtherCAT XML (ESI) device description file. Compatible with SMC New SY, SV, VQC and S0700 series manifold solenoid valves (same connectable manifolds as EX250).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX260-SEC1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX260SEC1\u003c\/p\u003e\u003ch2\u003eEX260-SEC1 Applications\u003c\/h2\u003e\u003cp\u003ePuts an SMC valve manifold directly on an EtherCAT network, driving up to 32 solenoids while its dual M12 BUS IN\/OUT ports allow daisy-chaining without external switches. Direct-Mode operation and IP67 protection make it well suited to fast, deterministic machine control mounted at the pneumatics in harsh or washdown areas. Commission with the SMC ESI file in the EtherCAT master; the EX260 supports New SY, SV, VQC and S0700 manifolds.\u003c\/p\u003e\u003ch2\u003eEX260-SEC1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX260-SEC1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSI Unit (32 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSource\/PNP (negative common)\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eDual M12 4-pin D-coded (BUS IN\/OUT)\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX260-SEC1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/catalog\/en\/directional\/EX260-EN\/6-1-1-p0789-0800-ex260_en\/data\/6-1-1-p0789-0800-ex260_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX260SEC1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774748846,"sku":"EX260SEC1","price":1647.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/JQ6SR6nMbMGLAT4nBKNLoyVWu5g6lt3x6CdKPSvuKRSrJc2ngfaIg7OL7NbP.jpg?v=1784196128"},{"product_id":"ex260spn1","title":"SMC EX260SPN1 (EX260-SPN1) - Serial Interface Unit, PROFINET","description":"\u003cp\u003eSMC EX260SPN1 Serial Interface Unit — PROFINET SI unit, 32 outputs. SMC EX260-SPN1 is a PROFINET serial interface (SI) unit for the EX260 integrated fieldbus system, controlling up to 32 solenoid valve outputs on SMC valve manifolds. Output type is Source\/PNP (negative common). It has standard dual-port PROFINET connectivity (two M12 4-pin D-coded sockets, PORT 1 and PORT 2) to eliminate external switches or branch connectors, plus a power supply connector carrying load voltage for valves and operating voltage for the SI unit. IP67 enclosure for dust and washdown protection. Configured via the SMC GSDML file. Compatible with SMC New SY, SV, VQC and S0700 series manifold solenoid valves (same connectable manifolds as EX250). The EX260 offers a compact, cost-effective output fieldbus solution across EtherNet\/IP, PROFINET, EtherCAT, PROFIBUS-DP, DeviceNet and CC-Link.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX260-SPN1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX260SPN1\u003c\/p\u003e\u003ch2\u003eEX260-SPN1 Applications\u003c\/h2\u003e\u003cp\u003eConnects an SMC valve manifold to a PROFINET network, driving up to 32 solenoids while its built-in dual PROFINET ports let nodes daisy-chain without extra switches. IP67 protection and machine-side mounting reduce valve wiring and cabinet space in dusty or washdown environments. Commission with the SMC GSDML file in the PROFINET controller; the EX260 supports New SY, SV, VQC and S0700 manifolds and is a common EX250 replacement.\u003c\/p\u003e\u003ch2\u003eEX260-SPN1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX260-SPN1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSI Unit (32 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSource\/PNP (negative common)\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eDual M12 4-pin D-coded (dual port)\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX260-SPN1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/www.smcworld.com\/catalog\/en\/directional\/EX260-EN\/6-1-1-p0789-0800-ex260_en\/data\/6-1-1-p0789-0800-ex260_en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX260SPN1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774814382,"sku":"EX260SPN1","price":1680.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/7zBlG3CAvpvAquJJ2XWzRagIl5IpxZTxRr420Tjp6jIrMPYcztETBGRWBjne.jpg?v=1784196129"},{"product_id":"ex260spr5","title":"SMC EX260SPR5 (EX260-SPR5) - SI Unit, PROFIBUS DP, D-sub Connector","description":"\u003cp\u003eSMC EX260SPR5 SI Unit — PROFIBUS DP integrated SI unit, output only, no built-in termination resistor. Integrated-type serial interface (SI) unit for PROFIBUS DP fieldbus communication. Output-only SI unit for EX250-series compatible valve manifolds (SY, SV, VQC, S0700 series). D-sub 9-pin communication connector. No built-in termination resistor (EX260-SPR5), external termination required. Power supply for SI unit operation 24 VDC, current consumption 0.1 A max. Enclosure IP67..\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX260-SPR5 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX260SPR5\u003c\/p\u003e\u003ch2\u003eEX260-SPR5 Applications\u003c\/h2\u003e\u003cp\u003eThe EX260-SPR5 is an integrated PROFIBUS DP serial interface unit that mounts directly onto SMC valve manifolds such as the SY, SV, VQC and S0700 series, reducing manifold wiring to a single fieldbus drop. As an output-only slave it drives up to the manifold's solenoid count over PROFIBUS DP. It suits distributed pneumatic control in packaging, assembly and process machinery where PLC-based fieldbus I\/O and space-saving wiring are required. External bus termination is needed on this variant.\u003c\/p\u003e\u003ch2\u003eEX260-SPR5 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX260-SPR5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eIntegrated SI unit (output)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX260\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eD-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX260-SPR5 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex260_profibus_en-h.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX260SPR5 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103774912686,"sku":"EX260SPR5","price":1379.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/xZF1YXmTy25Y0kt6YOEwjdmkEhVQl1KRdrY8NZICpE5h7jDQgdfuagxIS3ug.jpg?v=1784196130"},{"product_id":"ex500gpr1a","title":"SMC EX500GPR1A (EX500-GPR1A) - Gateway Unit, PROFIBUS DP","description":"\u003cp\u003eSMC EX500GPR1A Gateway Unit — PROFIBUS DP gateway (GW) unit, 4-branch reduced-wiring serial system. Gateway (GW) unit for the EX500 gateway-type serial transmission system, PROFIBUS DP compatible (EN 50170) slave. Connects up to 4 branches of SI units and input units to a PROFIBUS DP master. Communication speeds 9.6 kbps to 12 Mbps. Power supply 24 VDC. Slave address set by rotary switches. Enclosure IP65..\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX500-GPR1A · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX500GPR1A\u003c\/p\u003e\u003ch2\u003eEX500-GPR1A Applications\u003c\/h2\u003e\u003cp\u003eThe EX500-GPR1A is the PROFIBUS DP gateway unit at the head of an SMC EX500 reduced-wiring serial transmission system. It acts as a PROFIBUS DP slave, gathering I\/O from up to four branches of SI units and input units on distributed valve manifolds and consolidating them onto a single fieldbus drop. Rotary-switch addressing and IP65 construction make it suited to machine-mounted pneumatic control in packaging, automotive and general factory automation where wiring reduction and easy commissioning matter.\u003c\/p\u003e\u003ch2\u003eEX500-GPR1A Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX500-GPR1A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eGateway (GW) unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX500\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX500-GPR1A Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex500-gpr1a_tf2z133en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX500GPR1A · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775109294,"sku":"EX500GPR1A","price":5675.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/24_10_2024_12_06_44_EX500_GPR1A_SMC.jpg?v=1784196132"},{"product_id":"ex500ib1","title":"SMC EX500IB1 (EX500-IB1) - Input Manifold Unit, EX500 Input Manifold","description":"\u003cp\u003eSMC EX500IB1 Input Manifold Unit — Input block \/ input manifold base unit for EX500 serial system, up to 8 input blocks. Input unit (base) for the EX500 gateway-type serial transmission system. Accepts up to 8 input blocks for a maximum of 16 inputs. PNP (source, negative common) input. M12 communication connector to the GW unit. Power supply 24 VDC, input block current 0.5 A max. Enclosure IP67. Supplied with input unit, end block and DIN rail as an input manifold.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX500-IB1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX500IB1\u003c\/p\u003e\u003ch2\u003eEX500-IB1 Applications\u003c\/h2\u003e\u003cp\u003eThe EX500-IB1 is the input manifold base of an SMC EX500 serial transmission system, collecting sensor and switch signals into the fieldbus network. It accepts up to eight input blocks for a maximum of 16 digital inputs, connects to the gateway via an M12 communication connector, and is IP67 rated for machine-mounted use. It is applied in distributed pneumatic and sensor I\/O on packaging, automotive and material-handling equipment built around EX500 valve manifolds.\u003c\/p\u003e\u003ch2\u003eEX500-IB1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX500-IB1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX500 serial transmission\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eInput manifold base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX500\u003c\/td\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e16 max\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX500-IB1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex500-ix_tf2z132en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX500IB1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775240366,"sku":"EX500IB1","price":292.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/13_09_2024_11_32_04_EX500_IB1_SMC.png?v=1784196135"},{"product_id":"ex500ie1","title":"SMC EX500IE1 (EX500-IE1) - Input Block, EX500 Input Block, M8 Connector","description":"\u003cp\u003eSMC EX500IE1 Input Block — Extension input block, M8 connector, 2 inputs, PNP. Extension input block for the EX500 input unit (EX500-IB1) of the gateway-type serial transmission system. 2 input points via M8 3-pin connectors, PNP input. Input device supply 24 VDC. Green LED power indication. Enclosure IP65. Mounts onto the EX500 input manifold base.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX500-IE1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX500IE1\u003c\/p\u003e\u003ch2\u003eEX500-IE1 Applications\u003c\/h2\u003e\u003cp\u003eThe EX500-IE1 is a 2-point extension input block that mounts onto the EX500-IB1 input manifold in an SMC EX500 serial transmission system. It provides two PNP sensor inputs through M8 3-pin connectors with LED power indication and IP65 protection. Multiple blocks build up the manifold's input count. It is used to gather proximity, reed and other 3-wire sensor signals into the fieldbus network on machine-mounted pneumatic automation.\u003c\/p\u003e\u003ch2\u003eEX500-IE1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX500-IE1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX500 serial transmission\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eExtension input block\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX500\u003c\/td\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eM8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX500-IE1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex500-ix_tf2z132en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX500IE1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775371438,"sku":"EX500IE1","price":103.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/13_09_2024_11_33_43_EX500_IE1_SMC.jpg?v=1784196135"},{"product_id":"ex500ie5","title":"SMC EX500IE5 (EX500-IE5) - Input Block, EX500 Input Block, M12 Connector","description":"\u003cp\u003eSMC EX500IE5 Input Block — Extension input block, M12 connector, PNP sensor input. Extension input block for the EX500 input unit (EX500-IB1) of the gateway-type serial transmission system. PNP sensor input via M12 connector. Input device supply 24 VDC. Green LED power indication. Enclosure IP65. Mounts onto the EX500 input manifold base.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX500-IE5 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX500IE5\u003c\/p\u003e\u003ch2\u003eEX500-IE5 Applications\u003c\/h2\u003e\u003cp\u003eThe EX500-IE5 is an extension input block for the EX500-IB1 input manifold in an SMC EX500 serial transmission system, providing PNP sensor inputs through M12 connectors with LED power indication and IP65 protection. It expands the manifold's input capacity for gathering 3-wire sensor signals into the fieldbus network. It is used on machine-mounted pneumatic automation in packaging, automotive and assembly applications built around EX500 manifolds.\u003c\/p\u003e\u003ch2\u003eEX500-IE5 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX500-IE5\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX500 serial transmission\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eExtension input block\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX500\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX500-IE5 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex500-ix_tf2z132en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX500IE5 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775404206,"sku":"EX500IE5","price":182.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/11_03_2025_14_46_34_EX500_IE5.png?v=1784196136"},{"product_id":"ex500s001","title":"SMC EX500S001 (EX500-S001) - SI Unit, EX500 Serial System","description":"\u003cp\u003eSMC EX500S001 SI Unit — SI unit for valve manifold, 16-point output, EX500 gateway serial system. SI (serial interface) unit for SMC valve manifolds within the EX500 gateway-type serial transmission system. Communicates with the GW unit and drives up to 16 solenoid output points per manifold (SV and VQC series valves). Supports single and double solenoids. Enclosure IP65. Up to 4 SI-unit\/manifold branches per GW unit for 64-solenoid control.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX500-S001 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX500S001\u003c\/p\u003e\u003ch2\u003eEX500-S001 Applications\u003c\/h2\u003e\u003cp\u003eThe EX500-S001 is the SI unit that mounts on an SMC valve manifold (SV or VQC series) in an EX500 gateway-type serial transmission system. It communicates with the EX500 gateway unit and drives up to 16 solenoid outputs, supporting single and double solenoids. Up to four SI units connect to one gateway for 64-solenoid control. IP65 construction suits machine-mounted pneumatic control in packaging, automotive and general factory automation with reduced wiring.\u003c\/p\u003e\u003ch2\u003eEX500-S001 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX500-S001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEX500 serial transmission\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSI unit (valve manifold)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX500\u003c\/td\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX500-S001 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/content2.smcetech.com\/pdf\/EX500.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX500S001 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775666350,"sku":"EX500S001","price":587.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/11_03_2025_14_45_00_EX500_S001.png?v=1784196138"},{"product_id":"ex600dxpb","title":"SMC EX600DXPB (EX600-DXPB) - Digital Input Unit, 8 Inputs PNP, 4 x M12 Connector","description":"\u003cp\u003eSMC EX600DXPB Digital Input Unit — 8-input PNP digital input unit, 4 x M12 (5-pin), 2 inputs per connector. SMC EX600-DXPB digital input unit for the EX600 integrated I\/O fieldbus system. PNP (negative common) input, 8 input channels arranged as 2 channels per connector across 4 x M12 (5-pin) socket connectors. Rated input current 9 mA or less, input resistance 2.7 kOhm. Power supply voltage 24 VDC Class 2 (2 A). ON voltage\/current 17 V or more \/ 5 mA or more; OFF voltage\/current 5 V or less \/ 1 mA or less. Sensor supply 24 VDC from the control\/input power supply; compatible with 2-wire and 3-wire PNP sensors. Short-circuit protection. Enclosure IP67 (manifold assembly). Operating temperature -10 to 50 C. Operating humidity 35 to 85% RH (no dew condensation).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX600-DXPB · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX600DXPB\u003c\/p\u003e\u003ch2\u003eEX600-DXPB Applications\u003c\/h2\u003e\u003cp\u003eThe EX600-DXPB adds eight PNP digital inputs to an SMC EX600 fieldbus manifold, connecting sensors and auto switches through four M12 5-pin sockets with two channels each. It gathers field signals and passes them over the serial link to the EX600 SI unit, cutting point-to-point wiring on valve manifolds and remote I\/O stations. With IP67 sealing and short-circuit protection it suits factory automation, packaging and assembly machines where distributed sensor inputs must be consolidated onto DeviceNet, PROFINET, EtherNet\/IP or other networks.\u003c\/p\u003e\u003ch2\u003eEX600-DXPB Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX600-DXPB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDigital Input Unit\u003c\/td\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eEX600 Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePNP (negative common)\u003c\/td\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 (2 per connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003e4 x M12 (5-pin) socket\u003c\/td\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e9 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e2.7 kOhm\u003c\/td\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC Class 2 (2 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eON Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e17 V or more \/ 5 mA or more\u003c\/td\u003e\n\u003ctd\u003eOFF Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e5 V or less \/ 1 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67 (Manifold assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 C\u003c\/td\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e35 to 85% RH (no dew condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX600-DXPB Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/content2.smcetech.com\/pdf\/manuals\/EXxx-OMN0036im.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX600DXPB · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775731886,"sku":"EX600DXPB","price":920.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/LeiflGY0kdIoGcHQJXVVJKOfgzDUvd55CFIdXyWvAtNdpT3eYHyJs206JIyq.jpg?v=1784196139"},{"product_id":"ex600dxpc","title":"SMC EX600DXPC (EX600-DXPC) - Digital Input Unit, 8 Inputs PNP, 8 x M8 Connector","description":"\u003cp\u003eSMC EX600DXPC Digital Input Unit — 8-input PNP digital input unit, 8 x M8 (3-pin), 1 input per connector. SMC EX600-DXPC digital input unit for the EX600 integrated I\/O fieldbus system. PNP (negative common) input, 8 input channels arranged as 1 channel per connector across 8 x M8 (3-pin) socket connectors. Rated input current 9 mA or less, input resistance 2.7 kOhm. Power supply voltage 24 VDC Class 2 (2 A). ON voltage\/current 17 V or more \/ 5 mA or more; OFF voltage\/current 5 V or less \/ 1 mA or less. Sensor supply 24 VDC from the control\/input power supply; compatible with 2-wire and 3-wire PNP sensors. Short-circuit protection. Enclosure IP67 (manifold assembly). Operating temperature -10 to 50 C. Operating humidity 35 to 85% RH (no dew condensation).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX600-DXPC · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX600DXPC\u003c\/p\u003e\u003ch2\u003eEX600-DXPC Applications\u003c\/h2\u003e\u003cp\u003eThe EX600-DXPC adds eight PNP digital inputs to an SMC EX600 fieldbus manifold, using eight compact M8 3-pin sockets with one channel each for high-density sensor connection. It consolidates auto switch and sensor signals onto the EX600 serial link to the SI unit, reducing wiring on valve manifolds and remote I\/O. With IP67 sealing and short-circuit protection it suits packaging, assembly and material-handling machines where many discrete inputs must be gathered onto DeviceNet, PROFINET, EtherNet\/IP and similar networks.\u003c\/p\u003e\u003ch2\u003eEX600-DXPC Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX600-DXPC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDigital Input Unit\u003c\/td\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eEX600 Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePNP (negative common)\u003c\/td\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 (1 per connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003e8 x M8 (3-pin) socket\u003c\/td\u003e\n\u003ctd\u003eRated Input Current\u003c\/td\u003e\n\u003ctd\u003e9 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e2.7 kOhm\u003c\/td\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC Class 2 (2 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eON Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e17 V or more \/ 5 mA or more\u003c\/td\u003e\n\u003ctd\u003eOFF Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e5 V or less \/ 1 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67 (Manifold assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 C\u003c\/td\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e35 to 85% RH (no dew condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX600-DXPC Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/content2.smcetech.com\/pdf\/manuals\/EXxx-OMN0036im.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX600DXPC · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775830190,"sku":"EX600DXPC","price":920.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/Euaq8Tz6etWuVosPxmoGVZ1tWSPD86vYNWZUPuG2ewPfqL3vyaYTqDUisHZR.jpg?v=1784196140"},{"product_id":"ex600sdn1a","title":"SMC EX600SDN1A (EX600-SDN1A) - SI Unit for DeviceNet, DeviceNet Protocol, PNP 32 Outputs","description":"\u003cp\u003eSMC EX600SDN1A SI Unit for DeviceNet — DeviceNet SI unit, PNP (negative common) output, max 512 I\/O. SMC EX600-SDN1A serial interface (SI) unit for DeviceNet, EX600 integrated fieldbus system. Protocol DeviceNet Volume 1 (Ed. 2.1) \/ Volume 3 (Ed. 1.1); device type communication adapter; slave Group 2 Only Server. Communication speed 125 \/ 250 \/ 500 kbps. Configuration via EDS file. I\/O occupation area max 512 inputs \/ 512 outputs. PNP \/ source, negative common output; 32 outputs (8\/16\/24\/32 selectable). Load: solenoid valve with light\/surge voltage suppressor 24 VDC 1.5 W or less (SMC). Fail safe HOLD \/ CLEAR \/ Force ON. Short-circuit protection. DeviceNet power supply 11 to 25 VDC. Enclosure IP67 (manifold assembly). Operating temperature -10 to 50 C. Operating humidity 35 to 85% RH (no dew condensation). CE marking, UL (CSA) recognition.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX600-SDN1A · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX600SDN1A\u003c\/p\u003e\u003ch2\u003eEX600-SDN1A Applications\u003c\/h2\u003e\u003cp\u003eThe EX600-SDN1A is the DeviceNet SI (serial interface) unit that links an SMC EX600 valve manifold and its I\/O modules to a DeviceNet network, mapping up to 512 inputs and 512 outputs and driving up to 32 solenoid valve outputs (PNP, negative common). Configured by EDS file at 125\/250\/500 kbps, it centralises valve and sensor control over a single trunk, replacing multi-core wiring. Fail-safe HOLD\/CLEAR\/Force ON and IP67 sealing make it suited to packaging, automotive and general factory automation lines running DeviceNet.\u003c\/p\u003e\u003ch2\u003eEX600-SDN1A Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX600-SDN1A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSI Unit (Serial Interface)\u003c\/td\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eEX600 Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet (Vol.1 Ed.2.1 \/ Vol.3 Ed.1.1)\u003c\/td\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003ePNP \/ source (negative common)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e125 \/ 250 \/ 500 kbps\u003c\/td\u003e\n\u003ctd\u003eConfiguration File\u003c\/td\u003e\n\u003ctd\u003eEDS file\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eI\/O Occupation\u003c\/td\u003e\n\u003ctd\u003eMax 512 inputs \/ 512 outputs\u003c\/td\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e32 (8\/16\/24\/32 selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLoad\u003c\/td\u003e\n\u003ctd\u003eSolenoid valve 24 VDC 1.5 W or less\u003c\/td\u003e\n\u003ctd\u003eFail Safe\u003c\/td\u003e\n\u003ctd\u003eHOLD \/ CLEAR \/ Force ON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDeviceNet Power Supply\u003c\/td\u003e\n\u003ctd\u003e11 to 25 VDC\u003c\/td\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67 (Manifold assembly)\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCE marking, UL (CSA) recognition\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX600-SDN1A Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-sdnxa_tf2z158en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX600SDN1A · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103775928494,"sku":"EX600SDN1A","price":1642.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/zPIi1uwxMgQHHWQG2sOcnPhkicgc3ZacYwRmAgWL3aBhqVZZodsZWjCFkb1U.jpg?v=1784196141"},{"product_id":"ex600spn1","title":"SMC EX600SPN1 (EX600-SPN1) - SI Unit for PROFINET, PROFINET Protocol, PNP 32 Outputs","description":"\u003cp\u003eSMC EX600SPN1 SI Unit for PROFINET — PROFINET SI unit, PNP (negative common) output, max 512 I\/O. SMC EX600-SPN1 serial interface (SI) unit for PROFINET, EX600 integrated fieldbus system. Protocol PROFINET IO (PROFINET RT); communication speed 100 Mbps; configuration via GSDML file. I\/O occupation area max 512 inputs \/ 512 outputs. PNP \/ source, negative common output; 32 outputs. Load: solenoid valve with lamp and surge voltage suppressor 24 VDC 1.0 W or less (SMC). Internal current consumption (control\/input power) 120 mA or less. One SI unit connects a valve manifold with up to 32 outputs plus up to 10 input\/output\/I\/O units. Short-circuit protection. Enclosure IP67 (manifold assembly). Operating temperature -10 to 50 C. Storage temperature -20 to 60 C.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX600-SPN1 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX600SPN1\u003c\/p\u003e\u003ch2\u003eEX600-SPN1 Applications\u003c\/h2\u003e\u003cp\u003eThe EX600-SPN1 is the PROFINET SI (serial interface) unit that connects an SMC EX600 valve manifold and its I\/O modules to a PROFINET IO network at 100 Mbps, mapping up to 512 inputs and 512 outputs and driving 32 solenoid valve outputs (PNP, negative common). Configured by GSDML file, one unit supports a manifold plus up to ten I\/O modules, consolidating valve and sensor control onto a single Ethernet drop. IP67 sealing and short-circuit protection suit automotive, packaging and general factory automation on PROFINET.\u003c\/p\u003e\u003ch2\u003eEX600-SPN1 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX600-SPN1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSI Unit (Serial Interface)\u003c\/td\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eEX600 Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO (PROFINET RT)\u003c\/td\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003ePNP \/ source (negative common)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\u003c\/td\u003e\n\u003ctd\u003eConfiguration File\u003c\/td\u003e\n\u003ctd\u003eGSDML file\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eI\/O Occupation\u003c\/td\u003e\n\u003ctd\u003eMax 512 inputs \/ 512 outputs\u003c\/td\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLoad\u003c\/td\u003e\n\u003ctd\u003eSolenoid valve 24 VDC 1.0 W or less\u003c\/td\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eExpansion\u003c\/td\u003e\n\u003ctd\u003eManifold + up to 10 I\/O units\u003c\/td\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67 (Manifold assembly)\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX600-SPN1 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/installationmaintenance-manuals\/en\/im_ex600-spn1-2_tf2z175en.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX600SPN1 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103776026798,"sku":"EX600SPN1","price":2879.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/19_06_2023_14_37_23_EX600_SPN1_SMC.jpg?v=1784196142"},{"product_id":"ex245spr1x171","title":"SMC EX245SPR1X171 (EX245-SPR1-X171) - Fieldbus System SI Unit, PROFINET Protocol, AIDA Push-Pull Connectors","description":"\u003cp\u003eSMC EX245SPR1X171 Fieldbus System SI Unit — PROFINET protocol with AIDA push-pull connectors. PROFINET protocol, Max. 8 modules, 128 digital inputs, 64 digital outputs, M12 communication connectors x 2, 7\/8 inch power supply connector.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX245-SPR1-X171 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX245SPR1X171\u003c\/p\u003e\u003ch2\u003eEX245-SPR1-X171 Applications\u003c\/h2\u003e\u003cp\u003eThe SMC EX245SPR1X171 is a made-to-order PROFINET SI unit used in automotive body-in-white and general assembly lines where valve manifolds and I\/O modules are controlled over a single fieldbus drop. It is suited for AIDA-compliant automotive installations, distributed valve manifold control, and modular I\/O expansion of up to 8 modules. Its push-pull connectors allow one-touch installation and removal, cutting wiring time during line builds and changeovers, while the flexible module combination lets a single node serve 128 digital inputs and 64 digital outputs.\u003c\/p\u003e\u003ch2\u003eEX245-SPR1-X171 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX245-SPR1-X171\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFieldbus System SI Unit (Made To Order)\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX245\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSI Unit Specification\u003c\/td\u003e\n\u003ctd\u003eSPR1-X171\u003c\/td\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. Number of Modules\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eMax. Number of Digital Inputs\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. Number of Digital Outputs\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003eCommunication Connector\u003c\/td\u003e\n\u003ctd\u003eM12 connector: 2 pcs.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower Supply Connector\u003c\/td\u003e\n\u003ctd\u003e7\/8 inch connector: 1 pc.\u003c\/td\u003e\n\u003ctd\u003eStandard Compliance\u003c\/td\u003e\n\u003ctd\u003eAIDA specifications compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003ePush-pull connectors, one-touch installation and removal\u003c\/td\u003e\n\u003ctd\u003eMade To Order Suffix\u003c\/td\u003e\n\u003ctd\u003e-X171 (EX245-X171\/X172\/X35 Made To Order Fieldbus System SI Unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103952875694,"sku":"EX245SPR1X171","price":8267.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/03_07_2026_16_18_40_Untitled_03_luglio_2026_alle_ore_09.49.48_7.png?v=1784197224"},{"product_id":"ex600sen1x14","title":"SMC EX600SEN1X14 (EX600-SEN1-X14) - Fieldbus System SI Unit, Modbus\/TCP Protocol, IP67 Enclosure","description":"\u003cp\u003eSMC EX600SEN1X14 Fieldbus System SI Unit — Modbus\/TCP protocol variant for Henrob riveting equipment. Modbus\/TCP protocol, 100BASE-TX media, 10\/100 Mbps, max. 9 I\/O units, 32 solenoid coils, PNP output, IP67 enclosure, 24 VDC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e EX600-SEN1-X14 · \u003cstrong\u003eSKU:\u003c\/strong\u003e EX600SEN1X14\u003c\/p\u003e\u003ch2\u003eEX600-SEN1-X14 Applications\u003c\/h2\u003e\u003cp\u003eThe SMC EX600SEN1X14 is a made-to-order Modbus\/TCP SI unit built for Henrob self-pierce riveting equipment, used in automotive body assembly and joining cells. It is suited for distributed valve manifold control, riveting-station I\/O gathering, and modular expansion of up to 9 input\/output units on one network node. Its IP67 rating and PBT housing allow mounting directly in the debris-heavy zones around riveting heads, while short-circuit protection on the outputs guards up to 32 solenoid coils driven from a single Class 2 24 VDC supply.\u003c\/p\u003e\u003ch2\u003eEX600-SEN1-X14 Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSMC\u003c\/td\u003e\n\u003ctd\u003eManufacturer Part No.\u003c\/td\u003e\n\u003ctd\u003eEX600-SEN1-X14\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFieldbus System SI Unit (Made To Order)\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX600\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eFieldbus system Modbus\/TCP compatible SI unit for Henrob\u003c\/td\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX\u003c\/td\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e10 Mbps \/ 100 Mbps (Automatic\/Manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCommunication Type\u003c\/td\u003e\n\u003ctd\u003eFull duplex \/ half duplex (Automatic\/Manual)\u003c\/td\u003e\n\u003ctd\u003eIP Address Setting\u003c\/td\u003e\n\u003ctd\u003eDHCP; DIP switch 192.168.50.1 to 192.168.50.254\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. Number of I\/O Units\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eMax. Solenoid Valves\u003c\/td\u003e\n\u003ctd\u003e32 solenoid coils\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOutput Polarity\u003c\/td\u003e\n\u003ctd\u003ePNP (negative common)\u003c\/td\u003e\n\u003ctd\u003ePower Supply (Control and Input)\u003c\/td\u003e\n\u003ctd\u003e24 VDC, Class 2, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower Supply (Output)\u003c\/td\u003e\n\u003ctd\u003e24 VDC, Class 2, 2 A\u003c\/td\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA or less at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConnected Load\u003c\/td\u003e\n\u003ctd\u003e24 VDC, Class 2, 1.5 W or less per output\u003c\/td\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP67 (with manifold assembled)\u003c\/td\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePBT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 g or less\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 C (UL agreement temp. 0 to 50 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 C\u003c\/td\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e35 to 85% RH, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eApplicable Valve Series\u003c\/td\u003e\n\u003ctd\u003eVQC1000\/2000\/4000, SV1000\/2000\/3000, SY3000\/5000, S0700\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCE marking, UL (CSA), RoHS\u003c\/td\u003e\n\u003ctd\u003eMade To Order Suffix\u003c\/td\u003e\n\u003ctd\u003e-X14 (Modbus\/TCP compatible SI unit for Henrob)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cstyle\u003e.ha-2col{display:grid;grid-template-columns:1fr 1fr;gap:44px;margin-top:34px;align-items:start}@media(max-width:768px){.ha-2col{grid-template-columns:1fr;gap:28px}}.ha-xref{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 10px}.ha-xref-item{border:1px solid #e8e8e8;border-left:3px solid #e05a1e;border-radius:8px;padding:9px 16px;background:#fafafa;min-width:150px}.ha-xref-brand{display:block;font-size:11px;font-weight:800;letter-spacing:.6px;text-transform:uppercase;color:#e05a1e}.ha-xref-model{display:block;font-size:14.5px;font-weight:600;color:#1a1a1a;margin-top:2px}.ha-xref-note{font-size:12.5px;color:#777;margin:0}.ha-dl{display:inline-flex;align-items:center;gap:14px;background:#e05a1e;color:#fff!important;text-decoration:none!important;font-weight:700;font-size:15px;line-height:1.2;padding:15px 28px;border-radius:10px;box-shadow:0 3px 12px rgba(224,90,30,.28);transition:transform .16s,box-shadow .16s,background .16s}.ha-dl:hover{background:#c44d18;box-shadow:0 6px 18px rgba(224,90,30,.40);transform:translateY(-2px)}.ha-dl-ic{display:flex;align-items:center;justify-content:center;width:38px;height:38px;background:rgba(255,255,255,.18);border-radius:8px;flex-shrink:0}.ha-dl small{display:block;font-size:11.5px;font-weight:500;opacity:.92;letter-spacing:.3px;margin-top:2px}\u003c\/style\u003e\u003cdiv class=\"ha-2col\"\u003e\u003cdiv class=\"ha-col\"\u003e\n\u003ch2\u003eEX600-SEN1-X14 Datasheet \u0026amp; Manual\u003c\/h2\u003e\n\u003ca class=\"ha-dl\" href=\"https:\/\/static.smc.eu\/binaries\/content\/assets\/smc_global\/product-documentation\/operation-manuals\/en\/om_ex600-sen1-x14_modbustcp_en-a.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"ha-dl-ic\"\u003e\u003csvg width=\"22\" height=\"22\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003cpath d=\"M21 15v4a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2v-4\"\u003e\u003c\/path\u003e\u003cpolyline points=\"7 10 12 15 17 10\"\u003e\u003c\/polyline\u003e\u003cline x1=\"12\" y1=\"15\" x2=\"12\" y2=\"3\"\u003e\u003c\/line\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003cspan\u003eDownload Datasheet \u0026amp; Manual\u003csmall\u003eSMC EX600SEN1X14 · PDF · Official SMC document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":48103953072302,"sku":"EX600SEN1X14","price":5027.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0755\/7221\/5982\/files\/30_12_2024_11_36_31_EX600_SEN1_X14_SMC.jpg?v=1784197225"}],"url":"https:\/\/hydroair.ae\/collections\/fieldbus-modules.oembed","provider":"HydroAir","version":"1.0","type":"link"}